  Datasheet File OCR Text:
 version 1.1 01/99 ______________________________________________________________________________________________________
tfs246kc.doc
VI TELEFILTER Filter specification TFS 246 K1 1/4 ______________________________________________________________________________________________________
Measurement condition Ambient temperature: Input power level: Terminating impedance: 23 C 0 dBm 450 || -3.4 pF
Construction and pin connection see page 2
Characteristics Remark:
Reference level for the relative attenuation arel of the TFS 246 K1 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 246 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo.
Preliminary Data
______________________________________________________________________________________________________ 6 dB max 7 dB ae = amin Insertion loss (Reference level) ______________________________________________________________________________________________________ 246 MHz fo Center frequency fN 246 MHz Norminal frequency ______________________________________________________________________________________________________ Relative attenuation 246,0 MHz 80 kHz
arel
typ. value
limit
max 3
dB
246,0 MHz 200 kHz ... 246,0 MHz 400 kHz 12 min 10 dB 246,0 MHz 400 kHz ... 246,0 MHz 600 kHz 30 min 25 dB 246,0 MHz 600 kHz ... 246,0 MHz 1,6 kHz 35 min 31 dB 246,0 MHz 1,6 MHz ... 246,0 MHz 3 MHz 50 min 41 dB 246,0 MHz 3 MHz ... 246,0 MHz 25 MHz 55 min 50 dB ______________________________________________________________________________________________________ Group delay distortion
GDD
246,0 MHz 50 kHz 0,7 s max 1,2 s 246,0 MHz 75 kHz 1,1 s max 2,5 s ______________________________________________________________________________________________________ Operating temperature range - 20 C ... + 85 C ______________________________________________________________________________________________________ ca. - 0,036 ppm/K Temperature coefficient of frequency TC ______________________________________________________________________________________________________ Frequency inversion temperature + 20 ... + 30 C ______________________________________________________________________________________________________
Generated: Checked / approved:
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs246kc.doc
version 1.1 01/99 ______________________________________________________________________________________________________
VI TELEFILTER Filter specification TFS 246 K1 2/4 ______________________________________________________________________________________________________
Construction, pin connection and 50 matching network
TFS246K1 tft L1
Pinning - balanced
1 Output 2 Output 3 Ground 4 Ground 5 Ground 6 Input 7 Input 8 Ground 9 Ground 10 Ground
Pinning - unbalanced
1 10 9 8
50 test circuit (balanced)
C1 LB-IN 6 1 C3 LB-OUT
2
3
1 Output
4 5 7 6
6 Input
2 RF Return 7 RF-Return 3 Ground 4 Ground 5 Ground 8 Ground 9 Ground 10 Ground
L1
SAW
7 2
L2
C2 3,4,5,8,9,10
C4
50 test circuit (unbalanced)
L3 6 1 L4
SAW
C5 C6
2,3,4,5,7,8,9,10
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs246kc.doc
version 1.1 01/99 ______________________________________________________________________________________________________
VI TELEFILTER Filter specification TFS 246 K1 3/4 ______________________________________________________________________________________________________
Stability characteristics
After the following tests the filter shall meet the whole specification: 1. Shock: 30g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 150 Hz, 0.35 mm amplitude, 5g; 2 hours for 3 planes; DIN IEC 68 T2 - 6 90 % to 95 % rel. humidity, 40 C, 10 days; IEC Pub. 68 - 2 - 3
2. Vibration:
3. Damp heat:
4. Resistance to solder heat (Reflow):
260 C for 10 sec;
Packing
Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; pcs per reel: 2000
Tape (all dimensions in mm) W Po Do D1 E F P2 P1 Ao : : : : : : : : : 16 4 0,3 0,1
Do Po P2 EMBOSSED CARRIER TAPE
1,5 + 0,5
E
1,5 + 0,5 1,75 0,1 7,5 0,1 0,75 2 12 1,5 7,6 0,1
COVER TAPE 13,4
0,1
Ao F W
D1 Bo
G (min) :
0,1 0,1
P1
G
D1(min) :
W2
Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : : 330 16,4 +2 22,4 >= 90
C A N
13
0,25
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape.
Air reflow temperature conditions
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs246kc.doc
version 1.1 01/99 ______________________________________________________________________________________________________
VI TELEFILTER Filter specification TFS 246 K1 4/4 ______________________________________________________________________________________________________
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS246K1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X